Industrial valve engineering & manufacturing+86 130 4329 2503 · info@greysen.cn

Water Control Valves

Pressure Reducing Valve

Automatic control valve for stable downstream pressure in water distribution networks.

Pressure Reducing Valve

Engineered around the medium, pressure, temperature and operating duty.

Product overview

Pilot-operated automatic control valve that reduces a higher inlet pressure to a stable, adjustable downstream pressure as system demand changes.

Greysen reviews the complete operating case before confirming the valve. Body style, wetted materials, sealing system, connection standard and operator are matched as one project configuration.

Typical technical specification

Nominal sizeDN50โ€“DN800 (2โ€“32 in)
Pressure ratingPN10 / PN16 / PN25; higher classes by review
Body materialsDuctile iron, carbon steel or stainless steel
Disc / trimStainless trim with elastomer diaphragm and seals
Seat / sealingResilient or metal/resilient main-valve seat
End connectionFlanged
Design & testingEN 1074-5 / project specification; EN 12266-1 testing
Typical mediaClean water and compatible non-viscous liquids

DESIGN DETAILS

Features and benefits

01

Valve construction

Pilot system senses downstream pressure and modulates the main valve.

02

Sealing performance

Adjustable set point supports distribution-zone requirements.

03

Reliable operation

Stable control is maintained across changing flow demand.

04

Project flexibility

Optional gauges, strainers and pilot isolation simplify commissioning.

CONFIGURATION OPTIONS

Materials and sealing selection

Material combinations are reviewed against corrosion, erosion, temperature and required service life. The final approved data sheet defines every pressure-containing and wetted component.

Body

Ductile iron, carbon steel or stainless steel

Trim

Stainless trim with elastomer diaphragm and seals

Seat & seals

Resilient or metal/resilient main-valve seat

Connection

Flanged

VALVE + OPERATOR

Operation and automation

Manual and automated packages are selected using the valve operating load, maximum differential pressure, required speed and available site utilities.

Manual operation

Lever, handwheel or gearbox options are matched to size, torque and access.

Pneumatic actuation

Double-acting or spring-return packages can include solenoid, switch box and positioner.

Electric actuation

On/off or modulating actuators are configured for voltage, duty, enclosure and control signal.

Package verification

Torque or thrust, safety factor, mounting interface, travel time and fail position are checked together.

APPLICATION REVIEW

Information for correct selection

  1. Nominal size, pressure class and mating connection standard.
  2. Medium, concentration, solids and minimum/maximum temperature.
  3. Normal and maximum differential pressure, flow rate and cycle frequency.
  4. Manual or actuated operation, fail position, control signal and required travel time.

Typical applications

  • Water distribution zones
  • High-rise buildings
  • Irrigation systems
  • Industrial water supply

Engineering checks

  • Pressure-temperature suitability
  • Material and media compatibility
  • Flow velocity and operating load
  • Installation orientation and maintenance access

PROJECT SUPPORT

Technical documentation

Request the documents required for consultant review, procurement and site handover. Availability is confirmed for the selected product and order.

  • Product data sheet
  • General arrangement drawing
  • Installation and maintenance guidance
  • Test and material documents when specified
Configuration note: Published ranges describe common industry configurations. Final dimensions, pressure-temperature limits, materials, certifications and standards are confirmed against the enquiry and approved data sheet.

Talk to an engineer

Specify the right butterfly valve for your project.

Request a quotation