Industrial valve engineering & manufacturing+86 130 4329 2503 · info@greysen.cn

HVAC Valves

Double Regulating Valve

Commissioning and balancing valve for accurate hydronic flow adjustment.

Double Regulating Valve

Engineered around the medium, pressure, temperature and operating duty.

Product overview

Commissioning and balancing valve combining flow regulation, repeatable presetting and pressure measurement for hydronic HVAC systems.

Greysen reviews the complete operating case before confirming the valve. Body style, wetted materials, sealing system, connection standard and operator are matched as one project configuration.

Typical technical specification

Nominal sizeDN15–DN300 (½–12 in)
Pressure ratingTypically PN16 / PN25
Body materialsDZR brass, bronze, cast iron or ductile iron
Disc / trimCopper alloy or stainless stem and regulating plug
Seat / sealingEPDM or PTFE sealing elements
End connectionThreaded, grooved or flanged
Design & testingBS 7350 and project HVAC commissioning requirements
Typical mediaChilled water, heating water and water/glycol mixtures

DESIGN DETAILS

Features and benefits

01

Valve construction

Preset function enables return to the commissioned position.

02

Sealing performance

Integrated test points support differential-pressure measurement.

03

Reliable operation

Graduated handwheel assists accurate balancing and records.

04

Project flexibility

Drain and isolation options simplify system maintenance.

CONFIGURATION OPTIONS

Materials and sealing selection

Material combinations are reviewed against corrosion, erosion, temperature and required service life. The final approved data sheet defines every pressure-containing and wetted component.

Body

DZR brass, bronze, cast iron or ductile iron

Trim

Copper alloy or stainless stem and regulating plug

Seat & seals

EPDM or PTFE sealing elements

Connection

Threaded, grooved or flanged

VALVE + OPERATOR

Operation and automation

Manual and automated packages are selected using the valve operating load, maximum differential pressure, required speed and available site utilities.

Manual operation

Lever, handwheel or gearbox options are matched to size, torque and access.

Pneumatic actuation

Double-acting or spring-return packages can include solenoid, switch box and positioner.

Electric actuation

On/off or modulating actuators are configured for voltage, duty, enclosure and control signal.

Package verification

Torque or thrust, safety factor, mounting interface, travel time and fail position are checked together.

APPLICATION REVIEW

Information for correct selection

  1. Nominal size, pressure class and mating connection standard.
  2. Medium, concentration, solids and minimum/maximum temperature.
  3. Normal and maximum differential pressure, flow rate and cycle frequency.
  4. Manual or actuated operation, fail position, control signal and required travel time.

Typical applications

  • Chilled-water systems
  • Heating circuits
  • District energy
  • Commercial buildings

Engineering checks

  • Pressure-temperature suitability
  • Material and media compatibility
  • Flow velocity and operating load
  • Installation orientation and maintenance access

PROJECT SUPPORT

Technical documentation

Request the documents required for consultant review, procurement and site handover. Availability is confirmed for the selected product and order.

  • Product data sheet
  • General arrangement drawing
  • Installation and maintenance guidance
  • Test and material documents when specified
Configuration note: Published ranges describe common industry configurations. Final dimensions, pressure-temperature limits, materials, certifications and standards are confirmed against the enquiry and approved data sheet.

Talk to an engineer

Specify the right butterfly valve for your project.

Request a quotation